FastSeal(R) Bioabsorbable Vascular Access Closure System


Vascular Closure Systems, Inc, First in Human (FIH) Use of the FastSeal(R) Bioabsorbable Vascular Access Closure System -- 100% Success Rate, Including Patients with Challenging Anatomy and Vessel Condition.
The company is pleased to announce that after receiving Ethical Committee (EC) and Ministry of Health (MOH) approval, for the first human use of the company's FastSeal(R) Bioabsorbable Vascular Access Closure System, Phase I of the First in Human (FIH) clinical testing has been completed, with 100% successful results, and no adverse effects, including post procedural discomfort. The average Time to Hemostasis (TTH) was less than one minute. The clinical cases included vessels that were normal, diseased, severely fibrosed and with calcified plaque.
The initial series of human clinical cases were performed on Percutaneous Coronary Intervention (PCI) patients, by Prof. Alessandro Bortone of the Policlinico di Bari, University of Bari School of Medicine (IT). Phase II testing will begin within the next two weeks.
The detailed FIH test results will be presented at multiple upcoming medical conferences.
The company is planning to begin International commercialization (pending regulatory approval) during the fourth quarter of this year.
About FastSeal(R)
Our Bioabsorbable Vascular Access Closure System is packaged and used as a single piece unit, with no assembly required prior to use, and no separate deployment device is needed to be inserted into the puncture site. Simply insert the FastSeal(R) system into the hub of the procedural introducer sheath, and advance the attached plunger. The system design enables hemostasis within less than a minute after the non-collagen sealing element has been deployed. Our system doesn't require the use of a specific type or brand of vascular introducer sheath, and is compatible with any commercialized vascular introducer sheath with a useable length of between 10 to 12 cm. Once the sealing element has been deployed, no external compression is required. The inner vessel section of the sealing element is absorbed within 10 to 14 days. The remainder of the sealing element is completely absorbed within 21 days. The FastSeal(R) system has the ability to be removed after deployment (if desired), without causing trauma to the vessel or requiring a surgical intervention.

CSL Behring Data Shows 4-Factor Prothrombin Complex Concentrate Is Effective


Data presented by CSL Behring at the 2012 Thrombosis and Hemostasis Summit of North America (THSNA) showed that a balanced, human 4-factor prothrombin complex concentrate (PCC) is as effective as the current standard of treatment in stopping bleeding in patients receiving vitamin K antagonist therapy (i.e., warfarin). Currently in the United States, fresh frozen plasma is the standard treatment for warfarin reversal. The data are from the first and largest randomized clinical study to demonstrate the non-inferiority of 4-factor PCC to plasma through clinical endpoints and to show superiority through bioanalytical endpoints.
The Phase IIIb study results showed that the hemostatic efficacy of 4-factor PCC was comparable to plasma at 24 hours in patients who required urgent reversal of warfarin therapy (72.4 percent and 65.4 percent, respectively). Additionally, the co-primary efficacy endpoint analysis showed that the 4-factor PCC was superior in achieving target INR correction within 30 minutes at the end of infusion as compared to plasma (62.2 percent and 9.6 percent, respectively). Four-factor PCC was also superior to plasma in rapidly and safely raising the levels of clotting factors II, VII, IX, X, and anticoagulant Proteins C and S at the same 30 minutes post-treatment time point (p values<0.0001).
"Patients on warfarin therapy are susceptible to acute and serious bleeding. For the physician, quickly stopping that bleeding is absolutely critical," said Ravindra Sarode, M.D., Director of Transfusion Medicine and Hemostasis Reference Laboratory at the University of Texas, Southwestern Medical Center, who presented the data. "This trial demonstrates that 4-factor PCC may offer healthcare professionals an important new treatment advance over plasma in managing patient outcomes in an important critical care setting."
The study also found that PCC was well-tolerated in patients and that the incidences of severe treatment-emergent adverse events, serious adverse events and deaths were generally similar between the PCC and plasma groups. Also, PCC was shown to possibly reduce the risk of transfusion-associated circulatory overload - that is, when too much fluid is transfused or transfusion is too rapid, which can lead to cardiac events - when compared to plasma (8.7 percent compared to 19.3 percent, respectively).
"We are very encouraged by the results, as this is the first and largest randomized clinical study showing 4-factor PCC is highly effective in reducing INR and increasing factor levels to support hemostatic efficacy during warfarin-induced bleeding," said Russell Basser, M.D., Senior Vice President, Global Clinical R&D, at CSL Behring. "CSL Behring is advancing our investigational 4-factor PCC through rigorous clinical study with the goal of bringing to the United States a safe, effective new treatment option for people who are at risk of major bleeding that results from warfarin use."
About Prothrombin Complex Concentrate (PCC) (Human)
Prothrombin complex concentrates (PCC) are derived from human plasma. CSL Behring's investigational PCC contains four important pro-coagulant factors in significant quantities: Factor II (prothrombin), Factor VII, Factor IX and Factor X, as well as anticoagulant Proteins C and S.
Guidelines from the American College of Chest Physicians recommend 4-factor PCC, rather than plasma, for rapid reversal of anticoagulation in patients with vitamin K antagonist associated major bleeding. The guidelines also recommend the use of vitamin K (5 to 10 mg) administered by slow intravenous (IV) infusion rather than reversal with coagulation factors alone.
About the Study
This was an open-label, randomized, multicenter Phase IIIb study to assess the efficacy, safety and tolerance of human 4-factor prothrombin complex concentrate (PCC) to plasma for rapid reversal of acute major bleeding in patients receiving warfarin therapy. The study enrolled 212 patients. The primary endpoint was hemostatic efficacy with respect to the adequacy of stopping an ongoing major bleed within 24 hours from the start of infusion. The secondary endpoints evaluated plasma levels of major clotting factors (Factors II, VII, IX, X, proteins C and S); time to INR correction; number of transfusions, amount of blood products used, and hemostatic agents; and safety and tolerability (including all-cause mortality).

Tuesday, May 8, 2012

3 Chinese drug makers recall 13 chromium-tainted (porcine)gelatin products

Three pharmaceutical companies have recalled their chromium-contaminated drug capsules after authorities suspended sales of 13 types of problematic medicines.
Tonghua Yason Pharmaceuticals in Northeast China's Jilin province said the company decided to recall all tainted products made since 2010.
"Pharmaceutical producers do not possess the capability to examine capsules, so we just simply checked the quality report provided by capsule suppliers and then let them go," an anonymous official with the company's product quality department was quoted as saying by stcn.com, a website run by Securities Times.
But the company said the producer of the problematic capsules was a Zhejiang-based company and was not among those exposed by media.
China Central Television revealed in an investigative program on Sunday that nine pharmaceutical companies were packaging medicines with capsules made with industrial gelatin, which contains a much higher degree of chromium than edible gelatin.
The industrial gelatin was made from waste leather at plants in Jiangxi, Zhejiang and Hebei provinces, according to the report. (Pictured above: 
Huge piles of substandard leather scraps at the warehouse of Xueyang Gelatin and Glair Factory in Hengshui, Hebei province, were used to make gelatin that was sold to capsule makers. Wang Min / Xinhua).
Normally, capsules are made with material from animal bones.
Excessive intake of chromium can result in chronic diseases. 


Jilin-based Huinan Tianyu Pharmaceutical posted a statement on its website saying that it is recalling the batch of products exposed by CCTV, but "those products were not problematic because they were produced in 2009 and they accorded with the standards set in related code released in 2000".
The Chinese Pharmacopoeia, amended in 2010, permits no more than 2 milligram of chromium per 1 kilogram of medicine. Before that, the cap was 5 mg per 1 kg for heavy metal, but it had no specific stipulation about chromium, said the announcement.
The company's products were found with 3.54 mg of chromium per 1 kg of medicine.
Dandong Tongyuan Pharmaceutical in Northeast China's Liaoning province also announced the recall of its chromium-contaminated products, according to China News Service.
Xiuzheng Pharmaceutical Group in Jilin said in a statement on its website that the company has suspended sales of the problematic products but said "the capsule suppliers we pick are quality firms that meet all the country's standards and we are re-examining those products".
After the chromium scandal was exposed, websites for three pharmaceutical companies involved, including Xiuzheng, were hit by hackers.
Song Xunjie, a manager with Xueyang Gelatin and Glair Factory in Hebei province, was detained on Monday by police and suspected of setting fire to his factory to eliminate evidence.
The fire did not cause any casualties. The factory had suspended production and police sealed 200 tons of products there.
The factory mainly sold products in Beijing and Zhejiang, as well as cities such as Changzhou, Jiangsu province, and Xiamen, Fujian province, according to Xinhua News Agency.
Sun Zhongshi, an expert with the National Rational Drug Use Monitoring System under the Ministry of Health, said the drug watchdog paid more attention to the quality of medicine inside the capsules rather than the capsules themselves, and should draw a lesson from this scandal.

SOURCE: China Daily

Friday, May 4, 2012

Have J&J Learnt From Baxters Chinese Pig Heparin Experience ? ?


May 03, 2012 -- Johnson & Johnson (China) Investment Ltd announced today the acquisition of Guangzhou Bioseal Biotechnology Co Ltd, a biopharmaceutical company specialising in the design, development and commercialisation of a porcine plasma-derived biologic product for controlling bleeding during surgery.
Financial terms of the transaction were not disclosed.
The company said that the acquisition was completed after obtaining all necessary Chinese Government approvals.
Bioseal manufactures a porcine-derived fibrin sealant, BIOSEAL, currently the only porcine plasma-derived fibrin sealant approved for use in China. Fibrin sealants are used by surgeons as an adjunct to haemostasis for use in patients undergoing surgery, when control of bleeding by standard surgical techniques is ineffective or impractical.
Bioseal will work closely with Ethicon Inc, a Johnson & Johnson company, which offers a complete line of absorbable haemostats with a commitment to advancing the future of biosurgery beyond haemostasis, to seal leaks, join structures and enhance healing. The acquisition of Bioseal will reportedly complement Ethicon's existing biosurgery portfolio and will allow the business to immediately enter the fibrin sealant market in China, broaden product offerings and create an opportunity to increase global reach by introducing advanced biologic solutions that meet the various needs of more physicians and patients, throughout Asia and around the world.
This is reportedly the first acquisition in the medical device industry for Johnson & Johnson (China).
Remember this.... 

Tuesday, April 10, 2012

HemCon Medical Technologies, Inc. Files for Chapter 11


HemCon Medical Technologies, Inc. (“HemCon”) announced today that it filed a voluntary petition for Chapter 11 reorganization in U.S. Bankruptcy Court.
The filing comes following the U.S. Court of Appeals for the Federal Circuit (CAFC) en banc decision on March 15, 2012 which affirmed an award of $34.2 million in damages to Marine Polymer Technologies, Inc. in a patent infringement case initiated in 2006.
“Chapter 11 gives us the best opportunities to maximize the value of HemCon and to continue to conduct business operations while we restructure debt, costs and other obligations,” said Nick Hart, HemCon’s President and Chief Financial Officer. “In addition, HemCon is planning on filing a petition to request that the CAFC rehear its 5-5 decision on claim construction, in the patent infringement case.”
During the past year, HemCon reformulated its chitosan-derived product line, branded as HemCon® PRO products. The HemCon PRO chitosan-derived product line has been successfully introduced in the U.S. and is approved for European and Japanese distribution, allowing for uninterrupted supply of product. Similarly, HemCon will continue supporting the recently introduced GuardaCare®XR Surgical product, as well as all of its other product lines including HemCon Patch® PRO and ChitoGauze® PRO.
HemCon anticipates commencing Phase II clinical trials in June for its U.S. Army-funded Lyophilized Plasma product (LyP). The U.S. military believes that early administration of plasma has an important role in reducing battlefield mortality rates, and sees this program as a top research and development priority.
HemCon’s European subsidiary is not subject to the Chapter 11 proceedings and will continue to operate as previously, selling its oxidized cellulose-based products including GuardIVa® Antimicrobial Hemostatic IV Dressing, Synaero™ Hemostatic Gel, and the consumer products line.
HemCon Medical Technologies, Inc. ( www.hemcon.com ), founded in 2001, develops, manufactures, and markets innovative technologies that control bleeding resulting from trauma or surgery. HemCon products are designed for use by military and civilian first responders as well as medical professionals in hospital, dental and clinical settings where rapid control of bleeding is of critical importance. HemCon is headquartered in Portland, Ore., with additional commercial operations in Ireland and the Czech Republic.
SOURCE: HemCon Medical Technologies, Inc.

Tuesday, March 20, 2012

Kuros, Synthes to Co-Develop Bioactive Materials for Specified Applications

Swiss biomaterials firm Kuros Biosurgery and Synthes inked a license and development agreement under which they will work together commercialize Kuros’ synthetic matrix technology in specified fields. Kuros is focused on the development of biomaterials and bioactive-biomaterial combination products for trauma, wound, and spinal applications.

The firm’s candidates are based on a platform that allows the combination of either natural (fibrin) or synthetic matrices that enable the controlled release of active molecules. The active biologics are chemically linked into the biomaterials and can be further engineered to contain an enzymatically-sensitive degradation site between the active domain of the biologic and the linking site. In the case of the fibrin-based matrices, the degradation site is sensitive to enzymes activated by a patient’s own cells as they invade and degrade the matrix during the tissue repair process. The active domain of the biologic is then effectively released on cellular demand.

Similarly, for synthetic matrix-based products, the active biologic is attached using either entrapment or non-enzymatic chemical cross-linking to the matrix as it forms. As with the fibrin-bound bioactives, enzymatically sensitive degradation sites can also be engineered between the active domain and the linking site to enable release upon cellular demand.

Kuros has nine candidates in various stages of clinical development. Lead orthopedic trauma candidates KUR-111 and KUR-113 have met their primary endpoints in large Phase IIb clinical trials. Preparations for Phase III studies are ongoing. KUR-111 is an autograft replacement candidate comprising a fibrin matrix, variant parathyroid hormone (vPTH), and hydroxyapatite/calcium phosphate (HA/TCP) granules. KUR-113 is a fracture product in development for promoting bone repair in tibial shaft fractures, and comprises a fibrin matrix and a variant PTH, which is prepolymerized by the surgeon into a gel-like paste and then applied to the sites of fracture.

Kuros wound healing and sealant pipeline includes lead candidate KUR-023, a synthetic dural sealant that has successfully completed a European clinical study intended for CE Marking. Additional bone regenerating, wound, and burn healing products are also in development.

Saturday, March 17, 2012

The incredible value of blood saving....

Click to enlarge.... Bloodless surgery in US Jehovah's Witnesses results in Heart benefits.

Friday, March 9, 2012

Australasian alert for tainted blood

CSL contaminated batches of Albumin recalled after lengthy delays to notify.
Yesterday the Therapeutic Goods Administration (TGA) in Australia quarantined CSL Human Albumin solutions from further use while an assessment is carried out into the safety of the products.
That followed notification from CSL Biotherapies that some batches of the solutions manufactured before January 25 had been contaminated with coolant ethylene glycol, due to equipment failure.
As a result the TGA issued a recall to all hospitals throughout Australia, New Zealand, Hong Kong and Singapore for the albumin, the main protein in plasma, manufactured before January 25.
CSL had advised the TGA that levels of contamination were "very low" and adverse clinical effects appeared unlikely. So far, CSL had not found evidence of anyone who received the albumin suffering ill effects. Toxicity due to ethylene glycol would occur acutely and delayed effects beyond 72 hours would not be expected.
CSL was continuing further tests ''to quantify the levels of contamination and the extent of the batches affected''.
Today a New Zealand Ministry of Health spokesman said CSL had not yet identified any batches of albumin in the country that were affected, but testing was continuing.
Hospitals had been advised and were working with the New Zealand Blood Service to manage use of the existing stock.
The ministry was also "promptly" sourcing stock it could be sure of.
In Australia, the TGA said that as a result of the action to quarantine stocks, supplies of albumin may be limited in the immediate future.
Stocks in Australia were being quarantined from further use until safety implications had been fully assessed.
Advice released by the TGA last night on the effect of ethylene glycol said ingestion of the coolant could lead to acute renal failure and trigger symptoms consistent with alcohol intoxication.
The highest risk would be anticipated among those patients requiring the largest volumes of albumin.

Wednesday, February 15, 2012

TRALI - further evidence to minimize transfusion


TRALI 

Transfusion-Related Acute Lung Injury (TRALI) is a syndrome characterized by acute respiratory distress following transfusion. All plasma-containing blood products have been implicated including rare reports of IVIG and cryoprecipitate. It is a rare complication of allogeneic blood transfusion but the incidence has not been well established due to difficulty in defining the syndrome and to variable reporting mechanisms worldwide. Various studies have estimated the overall frequency of TRALI to be between 1/1,120 and 1/57,810 units transfused. However, there is wide discrepancy in the literature with the reported frequency is as low as 1/557,000 RBC units and as high as 1/432 platelet units.
TRALI is associated with a high morbidity with the majority of patients requiring ventilatory support. However, the lung injury is generally transient with PO2 levels returning to pretransfusion levels within 48 -96 hours and CXR returning to normal within 96 hours. TRALI is associated with a significant mortality rate, often approximated at 5 to 10%. Given the gains in safety made within the blood component production industry, particularly with respect to transmission of infectious diseases, TRALI is now among the three leading causes of transfusion related fatalities along with ABO incompatibility and bacterial contamination.


Transfusion-related acute lung injury and pulmonary edema in critically ill patients: a retrospective study.

Rana R, Fernández-Pérez ER, Khan SA, Rana S, Winters JL, Lesnick TG, Moore SB, Gajic O.

Source

Division of Pulmonary and Critical Care Medicine, Mayo Clinic College of Medicine, Rochester, Minnesota 55905, USA.

Abstract

BACKGROUND:

Using the recent Consensus Panel recommendations, we sought to describe the incidence of transfusion-related acute lung injury (TRALI) and transfusion-associated circulatory overload (TACO) in critically ill patients.

STUDY DESIGN AND METHODS:

Consecutive patients at four intensive care units (ICUs) who did not require respiratory support at the time of transfusion were identified with custom electronic surveillance system that prospectively tracks the time of transfusion and onset of respiratory support. Respiratory failure was defined as the onset of noninvasive or invasive ventilator support within 6 hours of transfusion. Experts blinded to specific transfusion factors categorized the cases of pulmonary edema as permeability edema (suspected or possible TRALI) or hydrostatic edema (TACO) according to predefined algorithm. In a nested case-control design, transfusion variables and lung injury risk factors were compared between the TRALI cases and controls matched by age, sex, and admission diagnosis.

RESULTS:

There were 8902 units transfused in 1351 patients of whom 94 required new respiratory support within 6 hours of transfusion. Among 49 patients with confirmed acute pulmonary edema, experts identified 7 cases with suspected TRALI, 17 patients with possible TRALI, and 25 cases with TACO. The incidence of suspected TRALI was 1 in 1271 units transfused; possible TRALI, 1 in 534 per unit transfused; and TACO, 1 in 356 per unit transfused. When adjusted for sepsis and fluid balance in a stepwise conditional logistic regression analysis, patients who developed acute lung injury (suspected or possible TRALI) received larger amount of plasma (odds ratio 3.4, 95% confidence interval 1.2-10.2, for each liter infused; p = 0.023).

CONCLUSION:

In the ICU, pulmonary edema frequently occurs after blood transfusion. The association between infusion of plasma and the development of suspected or possible TRALI may have important implications with regards to etiology and prevention of this syndrome.